Basic Info
Model NO. |
EN source |
Heating power |
about 36Kw |
Temperature control method |
losed loop PID programmable curve automatic temperature control |
Maximum temperature |
550℃ |
Temperature accuracy in the furnace |
±10℃ |
Ultimate vacuum |
≤ 133Pa (under empty furnace and room temperature) |
Working range |
≤420℃ (under vacuum condition), ≤550℃ (under normal pressure condition) |
Temperature accuracy in the furnace |
±5℃ |
Ultimate vacuum |
≤ 133Pa (under empty furnace and room temperature) |
Rated nitrogen filling pressure |
≤0.12MPa |
·Note: all the machines of our company are customized. Please consult the salesman for specific parameters
Product Description
01 Molecular sieve oven
Molecular sieve activation furnace is used for vacuum degassing and drying of molecular sieve for LNG cylinders.
02Insulation paper oven Equipment description
2
heat preservation system
4
hot air circulation system
6
charging and discharging system
03Insulation paper oven showThe exterior of the furnace body is made of Q235 steel plate, and the interior and air ducts are made of 304 stainless steel.
150mm thick aluminum silicate is used for heat preservation.
The vacuum system adopts 2x-70 bipolar rotary vane pump, equipped with corresponding vacuum valves and pipelines.
The heating system is made of nickel-chromium belts, and the heating part is suspended.
The hot air circulation system adopts a 2.2Kw high temperature sealed water-cooled circulation fan to realize internal gas circulation and ensure temperature uniformity.
The charging and discharging system can fill the furnace cavity with nitrogen, the restart pressure is adjustable, and the safety valve is configured.
The control system includes temperature controller, thyristor voltage regulator, paperless recorder, etc.
04Composition of molecular sieve activation furnace
2
Furnace and furnace lining insulation material
5
Stove and hot air circulation barrel
6
Cabinet and temperature and action control electrical
7